## Operation and maintenance

Vibroflex SM supports do not require maintenance, provided that the installation
and operating instructions are followed:

 * The load on the Vibroflex SM supports must always be transferred only through
   the upper distribution plate.
 * The static load on Vibroflex SM supports must not exceed the values indicated
   in the table.
 * Short-term dynamic peak loads up to three times exceeding the nominal values 
   do not cause residual deformations or changes in the dynamic properties of the
   supports.
 * The maximum permissible values of horizontal load on the Vibroflex SM support
   must not exceed 25% of the value of the acting vertical load.
 * When installing machines that generate horizontal forces, special types of supports
   are required. Proposals for installing such supports are available upon request.

## Environmental sustainability

Vibroflex SM supports are made of an elastic material that is resistant to oils,
greases, and moisture.
 However, contact with solvents should be avoided. Although
Vibroflex SM supports are moisture-resistant, they should not be continuously immersed
in water. Exposure to intense ultraviolet radiation may cause the elastomer layer
to discolor, but the physical properties of the supports will remain unchanged. 
The operating temperature of Vibroflex SM supports ranges from -30°C to +70°C.

#### 󠀁[Installation](https://uzbuild.com/en/vibroflex-sm-type-b/#1703502471736-99407dad-7507)󠁿

 * To attach Vibroflex SM supports to equipment, the upper distribution plate is
   provided with an M12 thread.
 * As a rule, securing Vibroflex SM supports to the foundation is not required. 
   In cases where structural or other requirements require the supports to be secured
   to the foundation, supports with a bottom metal plate (Type B) should be used.
 * Vibration-isolating mounts must rest completely on the underlying surface. Surfaces
   on which Vibroflex SM mounts are installed must be level and horizontal.
 * The supports are installed at least 2 cm away from adjacent building elements.
   The supports must be positioned under the machine to ensure uniform settlement
   of the elements under load.
 * The stability and robustness of machines with a small footprint and high centre
   of gravity must be further checked.

#### 󠀁[Video](https://uzbuild.com/en/vibroflex-sm-type-b/#1703573242039-317a211b-64f6)󠁿

https://youtube.com/watch?v=bJT2LceUq7g%3Fecver%3D2

#### 󠀁[Documents](https://uzbuild.com/en/vibroflex-sm-type-b/#1703053158754-6b20a25b-e7d6)󠁿

[[[Brochure "VIBROFLEX SM"](https://www.acoustic.ru/data/pdf/Vibroflex_SM.pdf)

[[[Download all certificates in one archive](https://www.acoustic.ru/data/goodscatalog/goods/228/certs/ru_228.zip)

### Certificates and patents (Russia)

#### Fire safety waiver letter

[[

[[[VIBROFLEX SM type B. Fire safety exemption letter](https://www.acoustic.ru/data/goodscatalog/goods/229/certs/880.pdf)

#### Hygiene certificate

#### 󠀁[󠀁[󠀁[󠀁[

[[[VIBROFLEX SM type B. Hygiene certificate](https://www.acoustic.ru/data/goodscatalog/goods/229/certs/1159.pdf)