#### 󠀁[Application](https://uzbuild.com/en/wired-mat-50-rolled-mats/#1594143352530-ca615d98-1375)󠁿

They are intended for thermal insulation and fire protection of chimneys, industrial
equipment, steel structures, flues, pipelines, and ventilation equipment.

 

#### 󠀁[Technical specifications](https://uzbuild.com/en/wired-mat-50-rolled-mats/#1594143352541-c43af4e2-30c8)󠁿

  |  Mounting compaction coefficient |   |  1,2 |  
 |

  |  
 |  Product type |   |  Stitched mat made of stone wool with a metal mesh covering |   |  
 |

 

 

 

  |  
 |  Nominal density, kg/m³ |   |  50 |   |  
 |

 

 

 

  |  
 |  Fire hazard class of the material (flammability group) |   |  KM0 (NG) |   |  
 |

 

 

 

  |  
 |  Maximum operating temperature, C° |   |  520±10°C |   |  
 |

 

 

 

  |  
 |  Water absorption during short-term and partial immersion, kg/m², no more than |   |  1,0 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (100°C) |   |  0,048 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (150°C) |   |  0,056 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (200°C) |   |  0,068 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (250°C) |   |  0,081 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (300°C) |   |  0,096 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (350°C) |   |  0,114 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (400°C) |   |  0,132 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (500°C) |   |  0,178 |   |  
 |

 

 

 

  |  
 |  Thermal conductivity coefficient λ, W/m*K (50°C) |   |  0,040 |

#### 󠀁[Package](https://uzbuild.com/en/wired-mat-50-rolled-mats/#1594143453135-3f34f1c5-6afa)󠁿

  |  Article |  Packaging, kg |  Thickness, mm |  Packaging, m² |  Packaging, m³ |  Length, mm |  Width, mm |  
   |  210360 |  10 |  100 |  2 |  0.2 |  2000 |  1000 |  
 |  229085 |  9 |  90 |  2 |  0.18 |  2000 |  1000 |  
 |  218946 |  8 |  80 |  2 |  0.16 |  2000 |  1000 |  
 |  100296 |  14 |  70 |  4 |  0.28 |  4000 |  1000 |  
 |  100292 |  13.5 |  60 |  4.5 |  0.27 |  4500 |  1000 |  
 |  100290 |  12.5 |  50 |  5 |  0.25 |  5000 |  1000 |

#### 󠀁[Installation](https://uzbuild.com/en/wired-mat-50-rolled-mats/#1594143488706-2d101ef8-f355)󠁿

## Installation of ROCKWOOL LIGHT BATTS insulation

#### 󠀁[Brochures](https://uzbuild.com/en/wired-mat-50-rolled-mats/#1594145887531-4c288c6e-a08a)󠁿

[⌊icon⌉⌊icon⌉[

##### 󠀁[WIRED MAT 50](https://rwl.ru/files/rw/documents/wired-mat-50%20-%208748.pdf)󠁿

[⌊icon⌉⌊icon⌉[

##### 󠀁[EcoMaterial Absolute Certificate of Conformity](https://rwl.ru/files/rw/documents/sertifikat-sootvetstviya-ecomaterial-absolute%20-%204745.pdf)󠁿

[⌊icon⌉⌊icon⌉[

##### 󠀁[Technical assessment](https://rwl.ru/files/rw/documents/tekhnicheskaya-otsenka%20-%204776.pdf)󠁿

[⌊icon⌉⌊icon⌉[

##### 󠀁[ROCKprotect Thermal insulation protection for equipment and pipelines](https://rwl.ru/files/rw/documents/rockprotect-zashchita-teploizolyatsii-oborudovaniya-i-truboprovodov%20-%204456.pdf)󠁿