### Dimensions:

Working panel size (excluding ridge area): 1200 x 600 mm
 Thickness of sandwich 
panel mounted on a flat surface: 42.5 mm Thickness of system mounted on a flat surface
with a finishing layer of gypsum board: 55-105 mm

### Physical characteristics:

Panel weight: 20.5 kg
 System surface density: 39 kg/m2

### Fire safety:

Fire hazard class – KM1. (Certificate of Conformity No. C-RU.Pb97.V.01125)**

### Eco-friendliness:

The material complies with the unified SanEiG requirements for goods subject to 
sanitary and epidemiological supervision (expert opinion No. 2693-6 issued by the
Center for Hygiene and Epidemiology in the Moscow Region).

### Airborne noise insulation:

Acoustic tests were carried out by the acoustics laboratory of NNGASU, Nizhny Novgorod:

  |  Frequency, Hz |  100 |  125 |  160 |  200 |  250 |  315 |  400 |  500 |  
 |  wall made of 120 mm sand-lime brick (Rw = 50 dB) |  41 |  42 |  39 |  39 |  44 |  41 |  42 |  42 |  
 |  wall made of sand-lime brick 120 mm + ZIPS-Z4 42 mm + AKU-line 12.5 mm (Rw = 68 dB) |  41 |  47 |  49 |  53 |  60 |  64 |  66 |  70 |  
 |  Frequency, Hz |  630 |  800 |  1000 |  1250 |  1600 |  2000 |  2500 |  3150 |  
 |  120 mm sand-lime brick wall (Rw = 50 dB) |  45 |  49 |  51 |  55 |  57 |  60 |  64 |  66 |  
 |  wall made of sand-lime brick 120 mm + ZIPS-Z4 42 mm + AKU-line 12.5 mm (Rw = 68 dB) |  74 |  79 |  83 |  87 |  90 |  92 |  93 |  92 |

Index of additional insulation of airborne noise of the ZIPS-Z4 panel system: ΔRw
= 16 – 19 dB depending on the degree of unevenness of the wall or ceiling ^(*)

* the greater the distance between the Z4 panel and the surface, the higher the 
additional sound insulation index.

#### 󠀁[Equipment](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704432862960-002f6a3f-a578)󠁿

 * **The mounting kit for ZIPS Z4 includes:**
 *   |  Name |  Photo |  Quantity |  
      |  Universal self-tapping screw ∅4.8×110
   mm |   |  8 pcs. |  
    |  Universal self-tapping screw ∅4.8×140 mm |   |  8 pcs.
   |  
    |  Fischer universal dowel ∅8×50 mm |   |  8 pcs. |  
    |  Self-tapping screw
   for gypsum fiber board ∅3×30 mm |   |  10 pcs. |  
    |  Self-tapping screw for
   Aku-Line gypsum board ∅3.9×41 mm |   |  25 pcs. |  
    |  Extended washer M5 |   
   |  8 pcs. |  
    |  M8 washer |   |  2 pcs. |  
    |  ST support |   |  6 pcs. |  
   
   |  Metal anchor ∅8×92 mm |   |  2 pcs. |  
    |  Metal anchor ∅8×112 mm |   |  
   2 pcs. |

#### 󠀁[Installation](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704517376252-8ed6b5bc-2b5e)󠁿

 * The ZIPS-Z4 panel system is installed on existing walls made of concrete, gypsum
   blocks, or brick, reinforced concrete monolithic columns, and interfloor slabs.
   No preliminary alignment of walls or ceilings is required. Using a standard fastener
   kit, surface differences and slopes of up to 20 mm can be compensated. It is 
   not recommended to install the panel system on load-bearing structures less than
   80 mm thick. Using additional self-adhesive ST spacers, differences of up to 
   50 mm can be compensated. In this case, longer universal screws should also be
   used to secure the panels.
 * The ZIPS-Z4 soundproofing system should be attached to the side walls, floor,
   and ceiling using two layers of Vibrostek-M 100 vibration-insulating tape. The
   tape is applied and secured with Vibrosil sealant. Utilities adjacent to the 
   ZIPS panels are also wrapped with two layers of Vibrostek-M.
 * Before installation, use a laser axis plotter to create a plane 100-150 mm from
   the wall/ceiling. Next, find the minimum distance from the surface to be insulated
   to the laser beam and subtract 43 mm (the thickness of the Z4 sandwich panel)
   from it. This value is the distance from the laser plane to the surface of the
   ZIPS panels being installed. For this installation, it should be measured using
   a template (ruler) across the entire surface of the wall being covered.
 * Sandwich panels are installed from the bottom up, left to right. The first panel
   has its ridges trimmed along both the short and long sides, while subsequent 
   panels in the first row have their ridges trimmed only along the long side. After
   determining the maximum difference, the first ZIPS-Z4 panel is positioned and
   secured using a previously prepared template (ruler). For differences in the 
   protected surface of ≤ 20 mm, a panel with standard supports is used. Where panel
   offsets exceed 20 mm, 10 mm thick ST spacers (included in the fastener kit) are
   additionally glued to the adjustable supports (maximum of 3 per support). Each
   sandwich panel has 8 vibration units for securing it to the insulated surface
   and 6 adjustable supports. Panels must be installed using the vibration units
   only.
 * After the panel is positioned against the surface to be insulated, drill 8 mm
   diameter holes directly through the existing vibration damping units. Fasteners
   are inserted into the holes, driven in until they stop, and screwed into the 
   vibration damping unit with a conical washer placed under the screw head. When
   tightening the screws, leave a 3-4 mm gap between the screw head and the surface
   of the vibration damping unit to allow for further adjustment of the offset. 
   Then, using a 3 mm Allen key, adjust the panel’s clearance from the surface to
   be insulated according to the designated plane by tightening and loosening the
   adjusting pins. When leveling the panel, use all six adjustable supports. After
   leveling the surface, recess the screw heads into the surface of the vibration
   damping unit by no more than 1-2 mm. When installing on the ceiling, after adjustments
   are completed, the two central nodes of the ZIPS-Z4 panels are secured with metal
   anchor screws in accordance with fire safety requirements. Subsequent panels 
   are installed in a similar manner, ensuring the surface plane is maintained using
   adjustable supports.
 * ZIPS-Z4 sandwich panels are joined together using a tongue-and-groove joint and
   further secured with 3×25 mm gypsum fiber board screws at 150 mm pitch. When 
   closing a row, the panel can be trimmed, with the trimmed portion carried over
   to the next row. The minimum allowable trimmed section of the panel is 200 x 
   600 mm and has two fastening points and two adjustable supports. Sandwich panels
   are cut using a jigsaw or circular saw. If the trim line overlaps the adjustable
   support locations, the supports must be removed and re-glued to the desired section,
   offset at least 50 mm from the trimmed edge. Trimmed sections larger than 400
   x 600 mm must have at least four supports. Adjustable supports. To install the
   support, a 50×50 mm piece of mineral wool is removed from the sound-absorbing
   layer on the back of the panel using a sharp knife. A 7 mm diameter hole is drilled
   in the gypsum fiber layer for the adjusting pin. The adjustable support is glued
   into the prepared location using Vibrosil vibroacoustic sealant or hot melt adhesive.
   Additional supports are removed from unused, trimmed panel sections.
 * The panels are installed with transverse joints staggered in adjacent rows. The
   joint stagger must be at least 250 mm.
 * After installation is complete, the gap between the screw heads and the panel
   surface should be additionally checked to avoid the formation of acoustic bridges.
 * If the sandwich panel is completely positioned on the wall surface, it is installed
   using only six vibration-damping fastening points (the central fastening points
   are not used). If the wall panel must be trimmed, all available fastening points
   are used. When installing on a floor, the fastening kit includes two types of
   anchor screws: standard (70 mm longer than the sandwich panel thickness) and 
   shortened ones, which are required for securing the panels through the central
   fastening points. Shortened anchor screws are used for installation on hollow-
   core slabs of interfloor floors.
 * A finishing layer of 12.5 mm thick AKU-Line sheets is secured to the surface 
   of the ZIPS-Z4 panels. The sheets should be bonded to adjacent surfaces using
   two layers of Vibrostek-M vibration-insulating tape, in accordance with Section
   2 of these instructions. When installing the AKU-Line sheets, use 3.9 x 41 mm
   self-tapping screws spaced 200 mm vertically and 400 mm horizontally. The screws
   should not hit the vibration units of the sandwich panels.
    Excess protruding
   Vibrostek-M tape is trimmed flush with the finishing layer of AKU-Line sheets.
   The joints are filled with vibroacoustic silicone sealant. If necessary, the 
   panel system surface is additionally leveled for the final finish.

#### 󠀁[Video](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704369992291-62466784-4862)󠁿

[https://www.youtube.com/watch?v=Njb8MTHh03U&ab_channel=AcousticGroup%28%D0%90%D0%BA%D1%83%D1%81%D1%82%D0%B8%D0%BA%D0%93%D1%80%D1%83%D0%BF%D0%BF%29](https://www.youtube.com/watch?v=Njb8MTHh03U&ab_channel=AcousticGroup%28%D0%90%D0%BA%D1%83%D1%81%D1%82%D0%B8%D0%BA%D0%93%D1%80%D1%83%D0%BF%D0%BF%29)

#### 󠀁[Documents](https://uzbuild.com/en/zips-z4-sandwich-panel/#1703053158754-6b20a25b-e7d6)󠁿

[[[Catalog of materials for sound and vibration insulation](https://www.acoustic.ru/data/pdf_files/katalogue_sound_vibro2017.pdf)

[[[[

[[[Technical data sheet ZIPS-Z4](https://www.acoustic.ru/data/goodscatalog/goods/364/pdfs/11.pdf)

[[[Download all certificates in one archive](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/ru_364.zip)

### Certificates and patents (Russia)

#### Acoustic measurement protocol

#### 󠀁[󠀁[󠀁[󠀁[

[[[ZIPS-Z4 sandwich panel. Acoustic measurement protocol](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/1437.pdf)

#### Fire Safety Certificate

[[

[[[ZIPS-Z4 sandwich panel. Fire safety certificate.](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/1912.pdf)

#### Fire Safety Declaration

[[

[[[Soundline-PGP Super, a soundproofing panel for thin walls and partitions. Fire safety certification.](https://www.acoustic.ru/data/goodscatalog/goods/267/certs/1880.pdf)

#### Certificate of Conformity

[[

[[[ZIPS-Z4, sandwich panel. Certificate of Conformity](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2183.pdf)

#### Expert opinion

#### 󠀁[󠀁[󠀁[󠀁[

[[[ZIPS-Z4 sandwich panel. Expert opinion](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2195.pdf)

#### Ecological certificate

[[

[[[ZIPS-Z4 sandwich panel. Environmentally certified.](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2461.pdf)