### Dimensions:

Working panel size (excluding ridge area): 1200 x 600 mm
 Thickness of sandwich 
panel mounted on a flat surface: 42.5 mm Thickness of system mounted on a flat surface
with a finishing layer of gypsum board: 55-105 mm

### Physical characteristics:

Panel weight: 20.5 kg
 System surface density: 39 kg/m2

### Fire safety:

Fire hazard class – KM1. (Certificate of Conformity No. C-RU.Pb97.V.01125)**

### Eco-friendliness:

The material complies with the unified SanEiG requirements for goods subject to 
sanitary and epidemiological supervision (expert opinion No. 2693-6 issued by the
Center for Hygiene and Epidemiology in the Moscow Region).

### Airborne noise insulation:

Acoustic tests were carried out by the acoustics laboratory of NNGASU, Nizhny Novgorod:

  |  Frequency, Hz |  100 |  125 |  160 |  200 |  250 |  315 |  400 |  500 |  
 |  wall made of 120 mm sand-lime brick (Rw = 50 dB) |  41 |  42 |  39 |  39 |  44 |  41 |  42 |  42 |  
 |  wall made of sand-lime brick 120 mm + ZIPS -Z4 42 mm + AKU-line 12.5 mm (Rw = 68 dB) |  41 |  47 |  49 |  53 |  60 |  64 |  66 |  70 |  
 |  Frequency, Hz |  630 |  800 |  1000 |  1250 |  1600 |  2000 |  2500 |  3150 |  
 |  120 mm sand-lime brick wall (Rw = 50 dB) |  45 |  49 |  51 |  55 |  57 |  60 |  64 |  66 |  
 |  wall made of sand-lime brick 120 mm + ZIPS -Z4 42 mm + AKU-line 12.5 mm (Rw = 68 dB) |  74 |  79 |  83 |  87 |  90 |  92 |  93 |  92 |

The index of additional insulation of airborne noise of the ZIPS -Z4 panel system:
ΔRw = 16 – 19 dB depending on the degree of unevenness of the wall or ceiling ^(*)

* the greater the distance between the Z4 panel and the surface, the higher the 
additional sound insulation index.

#### 󠀁[Equipment](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704432862960-002f6a3f-a578)󠁿

 * **The ZIPS Z4 mounting kit includes:**
 *   |  Name |  Photo |  Quantity |  
      |  Universal self-tapping screw ∅4.8×110
   mm |   |  8 pcs. |  
    |  Universal self-tapping screw ∅4.8×140 mm |   |  8 pcs.
   |  
    |  Fischer universal dowel ∅8×50 mm |   |  8 pcs. |  
    |  Self-tapping screw
   for gypsum fiber board ∅3×30 mm |   |  10 pcs. |  
    |  Self-tapping screw for
   Aku-Line gypsum board ∅3.9×41 mm |   |  25 pcs. |  
    |  Extended washer M5 |   
   |  8 pcs. |  
    |  M8 washer |   |  2 pcs. |  
    |  ST support |   |  6 pcs. |  
   
   |  Metal anchor ∅8×92 mm |   |  2 pcs. |  
    |  Metal anchor ∅8×112 mm |   |  
   2 pcs. |

#### 󠀁[Installation](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704517376252-8ed6b5bc-2b5e)󠁿

 * ZIPS -Z4 panel system is installed on existing walls made of concrete, gypsum
   block, or brick, reinforced concrete columns, and floor slabs. No preliminary
   alignment of walls or ceilings is required. Using a standard fastener kit, surface
   differences and slopes of up to 20 mm can be compensated. Mounting the panel 
   system on load-bearing structures less than 80 mm thick is not recommended. Using
   additional self-adhesive ST spacers, differences of up to 50 mm can be compensated.
   In this case, longer universal screws should also be used to secure the panels.
 * ZIPS -Z4 soundproofing system should be attached to the side walls, floor, and
   ceiling using two layers of Vibrostek-M 100 vibration-insulating tape. The tape
   is applied and secured with Vibrosil sealant. Utilities adjacent to the ZIPS 
   panels are also wrapped with two layers of Vibrostek-M.
 * Before installation, use a laser alignment tool to create a plane 100-150 mm 
   from the wall/ceiling. Next, find the minimum distance from the surface to be
   insulated to the laser beam and subtract 43 mm (the thickness of the Z4 sandwich
   panel) from it. This value is the distance from the laser plane to the surface
   of the ZIPS panels being installed. For this installation, use a template (ruler)
   to control the distance across the entire surface of the wall being covered.
 * Sandwich panels are installed from the bottom up, left to right. The tongues 
   of the first panel are trimmed along both the short and long sides, while subsequent
   panels in the first row are trimmed only along the long side. After determining
   the maximum difference, the first ZIPS -Z4 panel is positioned and secured using
   a previously prepared template (ruler). For differences in the protected surface
   of ≤ 20 mm, a panel with standard supports is used. Where panel differences exceed
   20 mm, additional 10 mm thick ST spacers (included in the fastener kit) are glued
   to the adjustable supports (maximum of 3 per support). Each sandwich panel has
   8 vibration units for securing it to the insulated surface and 6 adjustable supports.
   Panels must be installed using the vibration units only.
 * After the panel is positioned against the surface to be insulated, drill 8 mm
   diameter holes directly through the existing vibration damping units. Fasteners
   are inserted into the holes, driven in until they stop, and screwed into the 
   vibration damping unit with a conical washer placed under the screw head. When
   tightening the screws, leave a 3-4 mm gap between the screw head and the surface
   of the vibration damping unit to allow for further adjustment of the offset. 
   Then, using a 3 mm Allen key, adjust the panel’s clearance from the surface to
   be insulated according to the designated plane by tightening and loosening the
   adjusting pins. When leveling the panel, use all six adjustable supports. After
   leveling the surface, recess the screw heads into the surface of the vibration
   damping unit by no more than 1-2 mm. When installing on the ceiling, after adjustments
   are completed, the two central nodes of ZIPS -Z4 panels are secured with metal
   anchor screws in accordance with fire safety requirements. Subsequent panels 
   are installed in a similar manner, ensuring the surface plane is maintained using
   adjustable supports.
 * ZIPS -Z4 sandwich panels are joined together using a tongue-and-groove joint 
   and further secured with 3×25 mm gypsum fiber board screws at 150 mm pitch. When
   closing a row, the panel can be trimmed, with the trimmed portion carried over
   to the next row. The minimum allowable trimmed section of the panel is 200 x 
   600 mm and has two fastening points and two adjustable supports. Sandwich panels
   are cut using a jigsaw or circular saw. If the trim line overlaps the adjustable
   support locations, the supports must be removed and re-glued to the desired section,
   offset at least 50 mm from the trimmed edge. Trimmed sections larger than 400
   x 600 mm must have at least four supports. Adjustable supports. To install the
   support, a 50×50 mm piece of mineral wool is removed from the sound-absorbing
   layer on the back of the panel using a sharp knife. A 7 mm diameter hole is drilled
   in the gypsum fiber layer for the adjusting pin. The adjustable support is glued
   into the prepared location using Vibrosil vibroacoustic sealant or hot melt adhesive.
   Additional supports are removed from unused, trimmed panel sections.
 * The panels are installed with transverse joints staggered in adjacent rows. The
   joint stagger must be at least 250 mm.
 * After installation is complete, the gap between the screw heads and the panel
   surface should be additionally checked to avoid the formation of acoustic bridges.
 * If the sandwich panel is completely positioned on the wall surface, it is installed
   using only six vibration-damping fastening points (the central fastening points
   are not used). If the wall panel must be trimmed, all available fastening points
   are used. When installing on a floor, the fastening kit includes two types of
   anchor screws: standard (70 mm longer than the sandwich panel thickness) and 
   shortened ones, which are required for securing the panels through the central
   fastening points. Shortened anchor screws are used for installation on hollow-
   core slabs of interfloor floors.
 * A finishing layer of 12.5 mm thick AKU-Line sheets is secured to the surface 
   of ZIPS -Z4 panels. The sheets should be bonded to adjacent surfaces using two
   layers of Vibrostek-M vibration-isolating tape, in accordance with Section 2 
   of these instructions. When installing the AKU-Line sheets, use 3.9 x 41 mm self-
   tapping screws spaced 200 mm vertically and 400 mm horizontally. The screws should
   not hit the vibration units of the sandwich panels. Excess protruding Vibrostek-
   M tape is trimmed flush with the finishing layer of AKU-Line sheets. The joints
   are filled with vibroacoustic silicone sealant. If necessary, the surface of 
   the panel system is additionally leveled for the final finishing.

#### 󠀁[Video](https://uzbuild.com/en/zips-z4-sandwich-panel/#1704369992291-62466784-4862)󠁿

[https://www.youtube.com/watch?v=Njb8MTHh03U&ab_channel=AcousticGroup%28%D0%90%D0%BA%D1%83%D1%81%D1%82%D0%B8%D0%BA%D0%93%D1%80%D1%83%D0%BF%D0%BF%29](https://www.youtube.com/watch?v=Njb8MTHh03U&ab_channel=AcousticGroup%28%D0%90%D0%BA%D1%83%D1%81%D1%82%D0%B8%D0%BA%D0%93%D1%80%D1%83%D0%BF%D0%BF%29)

#### 󠀁[Documents](https://uzbuild.com/en/zips-z4-sandwich-panel/#1703053158754-6b20a25b-e7d6)󠁿

[[[Catalog of materials for sound and vibration insulation](https://www.acoustic.ru/data/pdf_files/katalogue_sound_vibro2017.pdf)

[[[[

[[[ZIPS -Z4 datasheet](https://www.acoustic.ru/data/goodscatalog/goods/364/pdfs/11.pdf)

[[[Download all certificates in one archive](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/ru_364.zip)

### Certificates and patents (Russia)

#### Acoustic measurement protocol

#### 󠀁[󠀁[󠀁[󠀁[

[[[ZIPS -Z4 sandwich panel. Acoustic measurement protocol](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/1437.pdf)

#### Fire Safety Certificate

[[

[[[ZIPS -Z4 sandwich panel. Fire safety certificate.](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/1912.pdf)

#### Fire Safety Declaration

[[

[[[Soundline-PGP Super, a soundproofing panel for thin walls and partitions. Fire safety certification.](https://www.acoustic.ru/data/goodscatalog/goods/267/certs/1880.pdf)

#### Certificate of Conformity

[[

[[[ZIPS -Z4 sandwich panel. Certificate of conformity.](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2183.pdf)

#### Expert opinion

#### 󠀁[󠀁[󠀁[󠀁[

[[[ZIPS -Z4 sandwich panel. Expert opinion](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2195.pdf)

#### Ecological certificate

[[

[[[ZIPS -Z4 sandwich panel. Environmentally certified.](https://www.acoustic.ru/data/goodscatalog/goods/364/certs/2461.pdf)